Radiator Wind Tunnel & Conditioned Air Supply Systems

Tested objects
Radiators, oil coolers, charge air coolers, Refrigerant condensers as single or frontend integrated objects. Integrated conditioning modules for oil, charge air, coolant.
Air circuit operating conditions:
- Temperature: Ambient to +60 °C
- Airflow: ≥ 20000 m³/h
- Radiator Load: up to 250 kW

Tested objects
Evaporators, heater cores or vehicle HVAC-modules, air cooled oil- or charge air coolers. High precision air conditioning for low flow applications with:
- Temperature: -30 °C to +60 °C
- Humidity: 5 to 30 g/kg in range from 10 °C to 60 °C
- Airflow: 80 to 800 m³/h